| Voltage/Current regulator |
| |
| Binding: |
| The regulator devices don't use the "compatible" property. The binding is done |
| by the prefix of regulator node's name, or, if this fails, by the prefix of the |
| regulator's "regulator-name" property. Usually the pmic I/O driver will provide |
| the array of 'struct pmic_child_info' with the prefixes and compatible drivers. |
| The bind is done by calling function: pmic_bind_childs(). |
| Example drivers: |
| pmic: drivers/power/pmic/max77686.c |
| regulator: drivers/power/regulator/max77686.c |
| |
| For the node name e.g.: "prefix[:alpha:]num { ... }": |
| - the driver prefix should be: "prefix" - case sensitive |
| - the node name's "num" is set as "dev->driver_data" on bind |
| |
| Example the prefix "ldo" will pass for: "ldo1", "ldo@1", "ldoreg@1, ... |
| |
| Binding by means of the node's name is preferred. However if the node names |
| would produce ambiguous prefixes (like "regulator@1" and "regualtor@11") and you |
| can't or do not want to change them then binding against the "regulator-name" |
| property is possible. The syntax for the prefix of the "regulator-name" property |
| is the same as the one for the regulator's node name. |
| Use case: a regulator named "regulator@1" to be bound to a driver named |
| "LDO_DRV" and a regulator named "regualator@11" to be bound to an other driver |
| named "BOOST_DRV". Using prefix "regualtor@1" for driver matching would load |
| the same driver for both regulators, hence the prefix is ambiguous. |
| |
| Optional properties: |
| - regulator-name: a string, required by the regulator uclass, used for driver |
| binding if binding by node's name prefix fails |
| - regulator-min-microvolt: a minimum allowed Voltage value |
| - regulator-max-microvolt: a maximum allowed Voltage value |
| - regulator-min-microamp: a minimum allowed Current value |
| - regulator-max-microamp: a maximum allowed Current value |
| - regulator-always-on: regulator should never be disabled |
| - regulator-boot-on: enabled by bootloader/firmware |
| - regulator-ramp-delay: ramp delay for regulator (in uV/us) |
| |
| Note |
| The "regulator-name" constraint is used for setting the device's uclass |
| platform data '.name' field. And the regulator device name is set from |
| it's node name. If "regulator-name" is not provided in dts, node name |
| is chosen for setting the device's uclass platform data '.name' field. |
| |
| Other kernel-style properties, are currently not used. |
| |
| Note: |
| For the regulator autoset from constraints, the framework expects that: |
| - regulator-min-microvolt is equal to regulator-max-microvolt |
| - regulator-min-microamp is equal to regulator-max-microamp |
| - regulator-always-on or regulator-boot-on is set |
| |
| Example: |
| ldo0 { |
| /* Optional */ |
| regulator-name = "VDDQ_EMMC_1.8V"; |
| regulator-min-microvolt = <1800000>; |
| regulator-max-microvolt = <1800000>; |
| regulator-min-microamp = <100000>; |
| regulator-max-microamp = <100000>; |
| regulator-always-on; |
| regulator-boot-on; |
| regulator-ramp-delay = <12000>; |
| }; |