iio: sca3000: Remove an erroneous 'get_device()'

commit 928edefbc18cd8433f7df235c6e09a9306e7d580 upstream.

This looks really unusual to have a 'get_device()' hidden in a 'dev_err()'
call.
Remove it.

While at it add a missing \n at the end of the message.

Fixes: 574fb258d636 ("Staging: IIO: VTI sca3000 series accelerometer driver (spi)")
Signed-off-by: Christophe JAILLET <christophe.jaillet@wanadoo.fr>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>

diff --git a/drivers/iio/accel/sca3000.c b/drivers/iio/accel/sca3000.c
index 4964561..7218acf 100644
--- a/drivers/iio/accel/sca3000.c
+++ b/drivers/iio/accel/sca3000.c
@@ -982,7 +982,7 @@
 	st->tx[0] = SCA3000_READ_REG(reg_address_high);
 	ret = spi_sync_transfer(st->us, xfer, ARRAY_SIZE(xfer));
 	if (ret) {
-		dev_err(get_device(&st->us->dev), "problem reading register");
+		dev_err(&st->us->dev, "problem reading register\n");
 		return ret;
 	}