| .. -*- coding: utf-8; mode: rst -*- | |
| .. _lirc_dev_intro: | |
| ************ | |
| Introduction | |
| ************ | |
| LIRC stands for Linux Infrared Remote Control. The LIRC device interface is | |
| a bi-directional interface for transporting raw IR and decoded scancodes | |
| data between userspace and kernelspace. Fundamentally, it is just a chardev | |
| (/dev/lircX, for X = 0, 1, 2, ...), with a number of standard struct | |
| file_operations defined on it. With respect to transporting raw IR and | |
| decoded scancodes to and fro, the essential fops are read, write and ioctl. | |
| Example dmesg output upon a driver registering w/LIRC: | |
| .. code-block:: none | |
| $ dmesg |grep lirc_dev | |
| rc rc0: lirc_dev: driver mceusb registered at minor = 0, raw IR receiver, raw IR transmitter | |
| What you should see for a chardev: | |
| .. code-block:: none | |
| $ ls -l /dev/lirc* | |
| crw-rw---- 1 root root 248, 0 Jul 2 22:20 /dev/lirc0 | |
| .. _lirc_modes: | |
| ********** | |
| LIRC modes | |
| ********** | |
| LIRC supports some modes of receiving and sending IR codes, as shown | |
| on the following table. | |
| .. _lirc-mode-scancode: | |
| .. _lirc-scancode-flag-toggle: | |
| .. _lirc-scancode-flag-repeat: | |
| ``LIRC_MODE_SCANCODE`` | |
| This mode is for both sending and receiving IR. | |
| For transmitting (aka sending), create a ``struct lirc_scancode`` with | |
| the desired scancode set in the ``scancode`` member, :c:type:`rc_proto` | |
| set the IR protocol, and all other members set to 0. Write this struct to | |
| the lirc device. | |
| For receiving, you read ``struct lirc_scancode`` from the lirc device, | |
| with ``scancode`` set to the received scancode and the IR protocol | |
| :c:type:`rc_proto`. If the scancode maps to a valid key code, this is set | |
| in the ``keycode`` field, else it is set to ``KEY_RESERVED``. | |
| The ``flags`` can have ``LIRC_SCANCODE_FLAG_TOGGLE`` set if the toggle | |
| bit is set in protocols that support it (e.g. rc-5 and rc-6), or | |
| ``LIRC_SCANCODE_FLAG_REPEAT`` for when a repeat is received for protocols | |
| that support it (e.g. nec). | |
| In the Sanyo and NEC protocol, if you hold a button on remote, rather than | |
| repeating the entire scancode, the remote sends a shorter message with | |
| no scancode, which just means button is held, a "repeat". When this is | |
| received, the ``LIRC_SCANCODE_FLAG_REPEAT`` is set and the scancode and | |
| keycode is repeated. | |
| With nec, there is no way to distinguish "button hold" from "repeatedly | |
| pressing the same button". The rc-5 and rc-6 protocols have a toggle bit. | |
| When a button is released and pressed again, the toggle bit is inverted. | |
| If the toggle bit is set, the ``LIRC_SCANCODE_FLAG_TOGGLE`` is set. | |
| The ``timestamp`` field is filled with the time nanoseconds | |
| (in ``CLOCK_MONOTONIC``) when the scancode was decoded. | |
| .. _lirc-mode-mode2: | |
| ``LIRC_MODE_MODE2`` | |
| The driver returns a sequence of pulse and space codes to userspace, | |
| as a series of u32 values. | |
| This mode is used only for IR receive. | |
| The upper 8 bits determine the packet type, and the lower 24 bits | |
| the payload. Use ``LIRC_VALUE()`` macro to get the payload, and | |
| the macro ``LIRC_MODE2()`` will give you the type, which | |
| is one of: | |
| ``LIRC_MODE2_PULSE`` | |
| Signifies the presence of IR in microseconds. | |
| ``LIRC_MODE2_SPACE`` | |
| Signifies absence of IR in microseconds. | |
| ``LIRC_MODE2_FREQUENCY`` | |
| If measurement of the carrier frequency was enabled with | |
| :ref:`lirc_set_measure_carrier_mode` then this packet gives you | |
| the carrier frequency in Hertz. | |
| ``LIRC_MODE2_TIMEOUT`` | |
| If timeout reports are enabled with | |
| :ref:`lirc_set_rec_timeout_reports`, when the timeout set with | |
| :ref:`lirc_set_rec_timeout` expires due to no IR being detected, | |
| this packet will be sent, with the number of microseconds with | |
| no IR. | |
| .. _lirc-mode-pulse: | |
| ``LIRC_MODE_PULSE`` | |
| In pulse mode, a sequence of pulse/space integer values are written to the | |
| lirc device using :ref:`lirc-write`. | |
| The values are alternating pulse and space lengths, in microseconds. The | |
| first and last entry must be a pulse, so there must be an odd number | |
| of entries. | |
| This mode is used only for IR send. | |
| ************************** | |
| Remote Controller protocol | |
| ************************** | |
| An enum :c:type:`rc_proto` in the :ref:`lirc_header` lists all the | |
| supported IR protocols: | |
| .. kernel-doc:: include/uapi/linux/lirc.h |