| * pid.c PID controller for testing cooling devices |
| * |
| * |
| * |
| * Copyright (C) 2012 Intel Corporation. All rights reserved. |
| * |
| * This program is free software; you can redistribute it and/or |
| * modify it under the terms of the GNU General Public License version |
| * 2 or later as published by the Free Software Foundation. |
| * |
| * This program is distributed in the hope that it will be useful, |
| * but WITHOUT ANY WARRANTY; without even the implied warranty of |
| * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the |
| * GNU General Public License for more details. |
| * |
| * Author Name Jacob Pan <jacob.jun.pan@linux.intel.com> |
| * |
| */ |
| |
| #include <unistd.h> |
| #include <stdio.h> |
| #include <stdlib.h> |
| #include <string.h> |
| #include <stdint.h> |
| #include <sys/types.h> |
| #include <dirent.h> |
| #include <libintl.h> |
| #include <ctype.h> |
| #include <assert.h> |
| #include <time.h> |
| #include <limits.h> |
| #include <math.h> |
| #include <sys/stat.h> |
| #include <syslog.h> |
| |
| #include "tmon.h" |
| |
| /************************************************************************** |
| * PID (Proportional-Integral-Derivative) controller is commonly used in |
| * linear control system, consider the the process. |
| * G(s) = U(s)/E(s) |
| * kp = proportional gain |
| * ki = integral gain |
| * kd = derivative gain |
| * Ts |
| * We use type C Alan Bradley equation which takes set point off the |
| * output dependency in P and D term. |
| * |
| * y[k] = y[k-1] - kp*(x[k] - x[k-1]) + Ki*Ts*e[k] - Kd*(x[k] |
| * - 2*x[k-1]+x[k-2])/Ts |
| * |
| * |
| ***********************************************************************/ |
| struct pid_params p_param; |
| /* cached data from previous loop */ |
| static double xk_1, xk_2; /* input temperature x[k-#] */ |
| |
| /* |
| * TODO: make PID parameters tuned automatically, |
| * 1. use CPU burn to produce open loop unit step response |
| * 2. calculate PID based on Ziegler-Nichols rule |
| * |
| * add a flag for tuning PID |
| */ |
| int init_thermal_controller(void) |
| { |
| int ret = 0; |
| |
| /* init pid params */ |
| p_param.ts = ticktime; |
| /* TODO: get it from TUI tuning tab */ |
| p_param.kp = .36; |
| p_param.ki = 5.0; |
| p_param.kd = 0.19; |
| |
| p_param.t_target = target_temp_user; |
| |
| return ret; |
| } |
| |
| void controller_reset(void) |
| { |
| /* TODO: relax control data when not over thermal limit */ |
| syslog(LOG_DEBUG, "TC inactive, relax p-state\n"); |
| p_param.y_k = 0.0; |
| xk_1 = 0.0; |
| xk_2 = 0.0; |
| set_ctrl_state(0); |
| } |
| |
| /* To be called at time interval Ts. Type C PID controller. |
| * y[k] = y[k-1] - kp*(x[k] - x[k-1]) + Ki*Ts*e[k] - Kd*(x[k] |
| * - 2*x[k-1]+x[k-2])/Ts |
| * TODO: add low pass filter for D term |
| */ |
| #define GUARD_BAND (2) |
| void controller_handler(const double xk, double *yk) |
| { |
| double ek; |
| double p_term, i_term, d_term; |
| |
| ek = p_param.t_target - xk; /* error */ |
| if (ek >= 3.0) { |
| syslog(LOG_DEBUG, "PID: %3.1f Below set point %3.1f, stop\n", |
| xk, p_param.t_target); |
| controller_reset(); |
| *yk = 0.0; |
| return; |
| } |
| /* compute intermediate PID terms */ |
| p_term = -p_param.kp * (xk - xk_1); |
| i_term = p_param.kp * p_param.ki * p_param.ts * ek; |
| d_term = -p_param.kp * p_param.kd * (xk - 2 * xk_1 + xk_2) / p_param.ts; |
| /* compute output */ |
| *yk += p_term + i_term + d_term; |
| /* update sample data */ |
| xk_1 = xk; |
| xk_2 = xk_1; |
| |
| /* clamp output adjustment range */ |
| if (*yk < -LIMIT_HIGH) |
| *yk = -LIMIT_HIGH; |
| else if (*yk > -LIMIT_LOW) |
| *yk = -LIMIT_LOW; |
| |
| p_param.y_k = *yk; |
| |
| set_ctrl_state(lround(fabs(p_param.y_k))); |
| |
| } |