  "commit": "22e6b2312d221376dcd98a8afb0f314b62d33a91",
  "tree": "73906c8f5f2a381fe085d3660ef333e99c871926",
  "parents": [
    "0c2a40e2fe4f4af0410f57e84b95b817ec15aa70"
  ],
  "author": {
    "name": "Guenter Roeck",
    "email": "guenter.roeck@ericsson.com",
    "time": "Sun Jul 03 13:08:03 2011 -0700"
  },
  "committer": {
    "name": "Guenter Roeck",
    "email": "guenter.roeck@ericsson.com",
    "time": "Sun Jul 10 08:54:29 2011 -0700"
  },
  "message": "hwmon: (pmbus) Improve auto-detection of temperature status register\n\nIt is possible that a PMBus device supports the READ_TEMPERATURE2 and/or\nREAD_TEMPERATURE3 registers but does not support READ_TEMPERATURE1.\nImprove temperature status register detection to address this condition.\n\nReported-by: Jean Delvare \u003ckhali@linux-fr.org\u003e\nSigned-off-by: Guenter Roeck \u003cguenter.roeck@ericsson.com\u003e\nAcked-by: Jean Delvare \u003ckhali@linux-fr.org\u003e\nCc: stable@kernel.org # 2.6.39+\n",
  "tree_diff": [
    {
      "type": "modify",
      "old_id": "931d940923aebb77c5b7d1d9bc029977c029dd14",
      "old_mode": 33188,
      "old_path": "drivers/hwmon/pmbus.c",
      "new_id": "9b1f0c37ef77bb22d0c14bcf43e891b7e7a6eb4f",
      "new_mode": 33188,
      "new_path": "drivers/hwmon/pmbus.c"
    }
  ]
}